db.shutdownServer()
On this page
Changed in version 5.0.
db.shutdownServer()
-
Shuts down the current
mongod
ormongos
process cleanly and safely. You must issue thedb.shutdownServer()
operation against the admin database.db.shutdownServer()
has this syntax:db.shutdownServer({ force: <boolean>, timeoutSecs: <int> })
The method takes these fields:
Field Description force Optional. Specify true
to force themongod
ormongos
to shut down. Force shutdown interrupts any ongoing operations on themongod
ormongos
and may result in unexpected behavior.timeoutSecs Optional. Starting in MongoDB 5.0, mongod
andmongos
enter a quiesce period to allow any ongoing database operations to complete before shutting down.
If amongod
primary receives a shut down request, the primary:- Attempts to step down to a secondary.
If the step down fails and a: - Enters the quiesce period.
- Ends any remaining database operations.
- Shuts down.
mongod
secondary ormongos
shut down request, the quiesce period is entered after a shut down was requested.
The quiesce period is specified by the:- timeoutSecs field if a
shutdown
ordb.shutdownServer()
command was run, or shutdownTimeoutMillisForSignaledShutdown
server parameter if aSIGTERM
signal was sent tomongod
, ormongosShutdownTimeoutMillisForSignaledShutdown
server parameter if aSIGTERM
signal was sent tomongos
.
mongod
ormongos
that is shutting down.
timeoutSecs specifies a time period in seconds. The default is:- 15 seconds starting in MongoDB 5.0.
- 10 seconds in MongoDB versions earlier than 5.0.
mongod
uses timeoutSecs as follows:- If the current node is the primary node of a replica set,
mongod
waits for a period of up to the number of seconds specified by the timeoutSecs field for an electable node to catch up before stepping down the primary node. For details about the catch up time, see replication lag. - If the current node is in the
SECONDARY
state after stepping down from being the primary, any remaining time specified in timeoutSecs is used for a quiesce period, which allows existing operations to complete. New operations are sent to other replica set nodes.
mongos
uses timeoutSecs as a quiesce period, which allows existing operations to complete. New operations are sent to othermongos
nodes. In MongoDB versions earlier than 5.0,mongos
shuts down immediately and does not use timeoutSecs.
In MongoDB 4.4 and earlier, for amongod
primary, timeoutSecs is the number of seconds the primary should wait for a secondary to catch up. If no secondaries catch up within the specified time, the command fails. Defaults to10
seconds. - Attempts to step down to a secondary.
This operation provides a wrapper around the shutdown
command.
Behavior
For a mongod
started with Authentication, you must run db.shutdownServer()
over an authenticated connection. See Access Control for more information.
For a mongod
started without Authentication, you must run db.shutdownServer()
from a client connected to the localhost interface. For example, run mongosh
with the --host "127.0.0.1"
option on the same host machine as the mongod
.
db.shutdownServer()
on Replica Set Members
db.shutdownServer()
fails if the mongod
replica set member is running certain operations such as index builds. You can specify force: true to force the member to interrupt those operations and shut down.
Shutting Down the Replica Set Primary, Secondary, or mongos
Starting in MongoDB 5.0, mongod
and mongos
enter a quiesce period to allow any ongoing database operations to complete before shutting down.
If a mongod
primary receives a shut down request, the primary:
-
Attempts to step down to a secondary.
If the step down fails and a:
-
Enters the quiesce period.
-
Ends any remaining database operations.
-
Shuts down.
For a mongod
secondary or mongos
shut down request, the quiesce period is entered after a shut down was requested.
The quiesce period is specified by the:
-
timeoutSecs field if a
shutdown
ordb.shutdownServer()
command was run, or -
shutdownTimeoutMillisForSignaledShutdown
server parameter if aSIGTERM
signal was sent tomongod
, or -
mongosShutdownTimeoutMillisForSignaledShutdown
server parameter if aSIGTERM
signal was sent tomongos
.
Clients cannot open new connections to a mongod
or mongos
that is shutting down.
timeoutSecs specifies a time period in seconds. The default is:
-
15 seconds starting in MongoDB 5.0.
-
10 seconds in MongoDB versions earlier than 5.0.
mongod
uses timeoutSecs as follows:
-
If the current node is the primary node of a replica set,
mongod
waits for a period of up to the number of seconds specified by the timeoutSecs field for an electable node to catch up before stepping down the primary node. For details about the catch up time, see replication lag. -
If the current node is in the
SECONDARY
state after stepping down from being the primary, any remaining time specified in timeoutSecs is used for a quiesce period, which allows existing operations to complete. New operations are sent to other replica set nodes.
Starting in MongoDB 5.0, mongos
uses timeoutSecs as a quiesce period, which allows existing operations to complete. New operations are sent to other mongos
nodes. In MongoDB versions earlier than 5.0, mongos
shuts down immediately and does not use timeoutSecs.
In MongoDB 4.4 and earlier, if running db.shutdownServer()
against the replica set primary, the operation implicitly uses replSetStepDown
to step down the primary before shutting down the mongod
. If no secondary in the replica set can catch up to the primary within 10
seconds, the shutdown operation fails. You can issue db.shutdownServer()
with force:
true to shut down the primary even if
the step down fails.
Warning
Force shutdown of the primary can result in the rollback of any writes not yet replicated to a secondary.
Access Control
To run db.shutdownServer()
on a mongod
enforcing Authentication, the authenticated user must have the db.shutdownServer()
privilege. For example, a user with the built-in role hostManager
has the appropriate permissions.
Examples
Shut down a mongod
db.getSiblingDB("admin").shutdownServer()
Force Shut Down a mongod
db.getSiblingDB("admin").shutdownServer({ "force" : true })
Shut Down a Primary mongod
With Longer Timeout
db.getSiblingDB("admin").shutdownServer({ "timeoutSecs": 60 })